Plumbing and central heating replies.
Boiler condensate pipe into gutter.
Is it a right way to install condensate line emptying into the gutter.
Almost certainly the biggest problem was caused by the snow in the gutter restricting the condensate pipe.
Joining the boiler discharge pipe and condensate pipe crappy 22 sep 2016 in forum.
Condensate should only be discharged into an outside drain if there isnt a means discharging condensate internally eg teeing into a waste pipe from a sink or washbasin due to the risk of freezing if terminated outside and also.
One of my jobs this summer is to move a neighbours condensate from the gutter re run it internally and plumb it into the bath waste.
Not aware of any reg that requires condensate to neutalized unless going into a soak away then it should have limestone chips in soakaway and be 500mm from foundations.
I could easily extend the gutter round the corner slightly and run the condensate drain along the extension wall and into the gutter where it would be out of sight and maintenance cost free.
I would put condensate pipe on slight downward angle into rainwater pipe.
Post jobs here find a renewable energy specialist plumbers directory listings plumbing advice forums plumbing forum plumbing advice forum sponsor news offers water regulations fittings pipes valves taps diy plumbing advice diy plumbing how to guides diy bathroom remodelling advice green energy forums ground sourced heat pumps renewable.
Installing boiler condensate discharge pipes key 1 boiler 2 visible air break at plug hole alternative connection can be below sink trap 3 75 mm sink basin bath or shower waste trap 4 sink basin bath or shower with integral overflow 5 open end of condensate discharge pipe direct into gully 25 mm min below grating but.
Boiler guy proposes running condensate pipe to the same drain that the gutters go into because the soil stack is hard to reach from the boiler s location.
It was not much fun in the snow trying to melt the condensate pipe in the gutter.
The rainwater leads directly into a drain into which kitchen sink washer water is also dumped.
The 3 4 inch pipe is sticking out about 2 inch and under ideal condition empty out the condensate through the downspout located about 5 feet away.